STEP #1 - Connect your MicroLogix to your PC using the required 1761-CBL cable
WILL MODBUS POLL WORK WITH A MICROLOGIX 1100 SOFTWARE
When configuring communications for the Allen-Bradley®, a communication cable and either the RSLogix™ 500 or RSLogix™ Micro software are required. Like I detailed in my post above, first I need the OP to confirm my question directly, is what I think you wish to do in fact what you do wish to do?Īnswer this first, so I know I understand you, and that you also understand my suggestion, before going deeper into providing any example code.In addition to cabling and interface setup, parametric changes are required within RSLogix™ 500 and Alarmware to synchronize the Modbus Drivers. Thus to advise using an array of floats will be the cause of great grief as Modbus will not interpret this data as floats. No, I can’t explain this because I know nothing of the modbus protocol
WILL MODBUS POLL WORK WITH A MICROLOGIX 1100 CODE
But the Modbus protocol need know nothing about this, as we will have code that will store the float at a register address using two locations, and then have the destination end use those same two registers to re-compile the data into a float data type. But by using two 16 bit words, we can hold the float. how can store as array _float instead of array of int?įor Modbus, you can not use floats directly with holding registers as these registers are only 16 bit but unspecified data type, and you can not hold a float in 16 bits.
WILL MODBUS POLL WORK WITH A MICROLOGIX 1100 32 BIT
Then, as I mentioned, have the Modbus master interpret those holding registers as 32 bit floating point values.įirst, just to be clear about data types. Just set up your Modbus register array using 16 bit words, but where you define the location of the floating point value or values, have your code store the 32 bit floats there. The data wil be transferred as normal 16 bit data to the other side, where you will then need to re-interpret this data as a 32 bit floating point value. If the float is 32 bits wide, then you need two contiguous 16 bit holding registers to store this. If so, then, you will know that holding registers are 16 bit words, and that you can use two of them to represent the float of 32 bits wide.
WILL MODBUS POLL WORK WITH A MICROLOGIX 1100 HOW TO
I am finding this thread confusing, but what I think you are wanting to know is how to get a data register holding a float value transferred using Modbus protocol using holding registers, is this correct? I noticed you used 'wanna' twice in this thread, so maybe English is not your first language and you may have picked up this bad use from someone else. The word you mean to use is 'want to', just in case you did not know. The word 'wanna' is not correct use of the English language. If i wanna store the value in other memory map address how can i store it.
![will modbus poll work with a micrologix 1100 will modbus poll work with a micrologix 1100](https://i.redd.it/2anmcv7xt0081.jpg)
Here temp is value float, i wanted to read temp value as it is in address of buffer during MODBUS read coil function.Īu16data=(int)(100*temp) convert to integer format & strore. If (millis() > tempus) digitalWrite(13, LOW ) Here simple code to read temprature sensor data lm 35 #include *reading of coil where i can succefully read value*/Īu16data=(int)(100*Current_Value1) Īu16data=(int)(100*Current_Value2)
![will modbus poll work with a micrologix 1100 will modbus poll work with a micrologix 1100](https://docs.factoryio.com/tutorials/allen-bradley/img/setting-up-micrologix/rslinx-device-found.png)
In loop function state = slave.poll( au16data,30 ) I have doubt in below part of conversion this code work on integer value Since i am new to modbus programming let me know how to resolve this? How could i convert & read in modbus protocol. i have totally 25 current parameter 1 voltage 1 temprature sensor All the values are in float only. how can i save data directly in float here. Now i have sensor output in float value & buffer it stores in int value.
![will modbus poll work with a micrologix 1100 will modbus poll work with a micrologix 1100](https://forum.hms-networks.com/uploads/default/original/2X/6/6bfea019bb733941eef54b88d10d6f437f605d0f.png)
Here is code for measuring string current using modbus protocol I have used the standard modbus library to interface modbus protocol.